SN-M-Series-520
Front panel | Rear panel | |
|
|
|
1: Serial port for access in console mode 2: USB 3.0 port 3: Button to reset the appliance to its factory settings (defaultconfig). 4: Reset button 5: USB-C port console access |
1: On/off switches 2: Sockets for mains power supply |
|
|
As the serial ports (1) and (5) allow access to the SNS firewall in console mode, users can connect to it from a PC.
On the powered off SNS firewall:
- Insert the USB drive into one of the USB 3.0 ports (2)
- Connect the serial port (1) to an RS232 serial port, or connect serial port (5) to a USB port on the computer, by using the serial cable provided with the SNS firewall.
- Launch a console emulator on the PC to access the SNS firewall (115,200 baud - 8N1).
- Power up the SNS firewall, which will immediately start running on the USB drive.
- Continue to the section Starting the restoration of the SNS firewall.