CONFIG PROTOCOL MODBUS PROFILE IPS MEMORYACCESS CONFIG
Level
asq,modify
History
Appears in 3.1.0
Description
Configure memory access by function code for MODBUS protocol
Usage
index=<profile index> [01=<value,range_min-range_max,...>] [02=<value,range_min-range_max,...>] [03=<value,range_min-range_max,...>] [04=<value,range_min-range_max,...>] [05=<value,range_min-range_max,...>] [06=<value,range_min-range_max,...>] [15=<value,range_min-range_max,...>] [16=<value,range_min-range_max,...>] [22=<value,range_min-range_max,...>] [23=<value,range_min-range_max,...>] [24=<value,range_min-range_max,...>] where value, range_min and range_max in [0..65535] and multiple address ranges and values can be defined
Returns
Error code
Example
CONFIG PROTOCOL MODBUS PROFILE IPS MEMORYACCESS 01=0-2000 index=1