Conditions of use (SNi10, SNi20, SNi40 and SNxr1200 models)
SNi10, SNi20, SNi40 and SNxr1200 firewalls have been built to run continuously, in a server room for SNi10, SNi20 and SNi40 appliances, or embedded for the SNxr1200 model.
IMPORTANT
When firewalls are in storage, they have to be powered up for a 24-hour period at least once every two years, to allow the internal electrolytic capacitors to reform. Failure to do so may compromise their reliability.
WARNING
The firewall must be installed in compliance with state-of-the-art conditions of secure installation, i.e., in protected premises with limited access. To guarantee the integrity of the product and to avoid compromising the security of your installation, all unauthorized access to the firewall must be prevented.
NOTE
Ensure that the cables do not obstruct passageways to prevent them from being pulled out or the product from falling.
Do not install and/or use your Stormshield firewall close to an area where inflammable objects are stored or used.
Your SNi10, SNi20 or SNi40 firewall is intended for industrial use (see product specifications), away from areas that may be vulnerable to rainfall, floods or excessive humidity. It must be installed away from sources of shocks, vibrations, and dust, in an environment where the temperature conforms to the product's specifications.
Your SNxr1200 firewall is a built-in system that must be installed under conditions that meet the environmental qualifications provided by Stormshield (upon request).
The ideal ambient temperature is around 25°C. The tables below set out the operational temperature, storage temperature and humidity level for SNi10, SNi20, SNi40 and SNxr1200 models.
SNi10, SNi20, SNi40, and SNxr1200 models
Model |
Operating temperature |
Relative humidity operating (%) |
Storage temperature |
Relative humidity storage (%) |
---|---|---|---|---|
SNi10 |
-20° to +60°C |
0% to 95% |
-40° to +85°C |
0% to 95% |
SNi20 |
-40° to +70°C |
|||
SNi40 |
-40° to +75°C |
5% to 95% |
The tables below set out the operational temperature, storage temperature and humidity level for the power adapter, which is sold separately.
Power adapter for SNi20 (optional) and SNi10 (industrial) models
Operating temperature |
Relative humidity operating (%) |
Storage temperature |
Relative humidity storage (%) |
---|---|---|---|
-30° to +60°C (-22° to +140°F) |
20% to 90% |
-40° to +85°C |
10% to 95% |
Power adapter for SNi40 models (optional)
Operating temperature |
Relative humidity operating (%) |
Storage temperature |
Relative humidity storage (%) |
---|---|---|---|
0° to +40°C |
10% to 90% |
-20° to +70°C |
10% to 90% |
Power adapter for SNxr1200 models (optional)*
Operating temperature |
Relative humidity operating (%) |
Storage temperature |
Relative humidity storage (%) |
---|---|---|---|
-30° to +70°C |
20% to 90% |
-40° to +85°C |
10% to 95% |
*approved only for pre-production
IMPORTANT
Avoid in particular direct exposure to sunlight. Always keep an adequate distance around the appliance (at least 50 mm for the SNxr1200 model) in order to guarantee a free flow of air, thereby preventing the possibility of overheating.
IMPORTANT
Do not place objects on your Stormshield Network Security appliance.
Stormshield Network Security appliances have been tested, and comply with the limits defined for Class A digital devices, in line with section 15 of the FCC regulation. The purpose of these limits is to provide reasonable protection from harmful interference that may arise when an appliance is used in a commercial environment. Stormshield Network Security firewalls generate, use and potentially emit radioelectric waves that may cause harmful interference to radio communications if not installed and used according to the instructions in the manual. Using your appliance in a residential area may cause harmful interference. If this is the case, the user will need to resolve these issues at his own expense.
Stormshield Network Security firewalls comply with the requirements set out in the European standard EN55032, Class A. In a residential environment, a Class A product may cause radioelectric interference, for which the user may need to take appropriate measures.