Shutting down

SN160, SN160W, SN210, SN210W, SN310, SN-S-Series-220 and SN-S-Series-320

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait for several minutes until the Online and Status LEDs go out. For this model, the LEDs shut off in the following order:

Online 1Status 2

The Power LED will stay lit if the product is powered up.

SN510, SN-XS-Series-170, SN-M-Series-520, SN710, SN-M-Series-720, SN-M-Series-920 and SNi10 models

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait a few minutes for all 3 LEDs – Online, Status and Power to go out. For these models, upon shutdown, the LEDs shut off in the following order:

Online 1 + Status 2Power 3

A beep will indicate that the appliance is in the process of shutting down.

SN910

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall.

A beep will indicate that the appliance is in the process of shutting down. Wait for several minutes until the Power LED goes out.

SN1100, SN2100, SN3100, SN-L-Series-2200, SN-L-Series-3200, SN-XL-Series-5200 and SN-XL-Series-6200 models

To shut down your firewall, press once on the power button located on the rear panel. Wait a few minutes for all 3 LEDs – Online, Status and Power to go out.

For these models, upon shutdown, the LEDs shut off in the following order:

Online 1 + Status 2Power 3

A beep will indicate that the appliance is in the process of shutting down (except on SN-L-Series-3200, SN-XL-Series-5200 and SN-XL-Series-6200 models).

SN6100

To shut down your firewall, press once on the power button located on the rear panel. Wait a few minutes for the 2 LEDs (Run and Power) to go out. For this model, the LEDs shut off in the following order:

Run 1Power 3

A beep will indicate that the appliance is in the process of shutting down.

SNi20

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait several minutes until the Run LED goes out and the Power LED turns to yellow. For this model, the LEDs shut off in the following order:

Run 1Power 3

The Power LED will stay yellow if the product is powered up.

SNi40

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait a few minutes for the 2 LEDs (Run and Power) to go out. For this model, the LEDs shut off in the following order:

Run 1Power 3

SNxr1200

Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait for several minutes until the Power LED goes out.

ON/OFF switch

Details Pin Signal
ON J2.10 POWER_BUTTON+