Shutting down
SN160, SN160W, SN210, SN210W, SN310, SN-S-Series-220 and SN-S-Series-320
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait for several minutes until the Online and Status LEDs go out. For this model, the LEDs shut off in the following order:
Online 1 → Status 2
The Power LED will stay lit if the product is powered up.
SN510, SN-XS-Series-170, SN-M-Series-520, SN710, SN-M-Series-720, SN-M-Series-920 and SNi10 models
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait a few minutes for all 3 LEDs – Online, Status and Power to go out. For these models, upon shutdown, the LEDs shut off in the following order:
Online 1 + Status 2 → Power 3
A beep will indicate that the appliance is in the process of shutting down.
SN910
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall.
A beep will indicate that the appliance is in the process of shutting down. Wait for several minutes until the Power LED goes out.
SN1100, SN2100, SN3100, SN-L-Series-2200, SN-L-Series-3200, SN-XL-Series-5200 and SN-XL-Series-6200 models
To shut down your firewall, press once on the power button located on the rear panel. Wait a few minutes for all 3 LEDs – Online, Status and Power to go out.
For these models, upon shutdown, the LEDs shut off in the following order:
Online 1 + Status 2 → Power 3
A beep will indicate that the appliance is in the process of shutting down (except on SN-L-Series-3200, SN-XL-Series-5200 and SN-XL-Series-6200 models).
SN6100
To shut down your firewall, press once on the power button located on the rear panel. Wait a few minutes for the 2 LEDs (Run and Power) to go out. For this model, the LEDs shut off in the following order:
Run 1 → Power 3
A beep will indicate that the appliance is in the process of shutting down.
SNi20
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait several minutes until the Run LED goes out and the Power LED turns to yellow. For this model, the LEDs shut off in the following order:
Run 1 → Power 3
The Power LED will stay yellow if the product is powered up.
SNi40
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait a few minutes for the 2 LEDs (Run and Power) to go out. For this model, the LEDs shut off in the following order:
Run 1 → Power 3
SNxr1200
Log in to the configuration interface. Go to System > Maintenance and click on Shut down the firewall. Wait for several minutes until the Power LED goes out.
![]() |
ON/OFF switch
|