SNi10, SNi20, SNi40, and SNxr1200 models
Before plugging in any devices
- Ensure that your Stormshield product and its accessories are not damaged.
- Ensure that the electrical characteristics of your product indicated on the product label are compatible with those of your power supply network
- The chassis of your product must be connected to a protective earth circuit, using rated minimum 1 mm² wire (16AWG) on SN-XS-Series-170, SNi10, SNi20, SNi40 and SNxr1200 models. Ensure that the connection is permanent and reliable, and that the protective earth circuit of your installation complies with safety standards in force.
- Before installing or removing your product, ensure that it has been turned off, and that all power supply connections have been removed.
- Equipment connected to a DC mains supply: please follow IEC, NEC, ANSI/NFPA 70 and CEC, Part I, C22.1 for all relevant field wiring instructions and cautions. The equipment must be installed by a qualified electrician Only the CEI standard applies to the SNxr1200.
- The equipment shall be connected to the DC mains supply with an approved switch or breaker and easily accessible.
- Only wires rated minimum 16AWG or 1 mm² must be used to connect the equipment to the DC mains supply on SN-XS-Series-170, SNi10, SNi20, SNi40 and SNxr1200 models.
Warranty and safety rules
Never take apart a Stormshield Network Security appliance on your own. Only Stormshield, which markets the Stormshield Network Security range, and its approved maintenance agents are authorized to do so. A seal label protects all Stormshield Network Security firewalls from being opened.
Your warranty will be rendered null and void as soon as you dismantle a Stormshield Network Security firewall on your own.
IMPORTANT
Never dismantle your Stormshield Network Security appliance, as doing so may cause hardware accidents and/or bodily harm.
IMPORTANT
Copper Ethernet cables connected to your Stormshield Network Security firewall must not be connected to other appliances located in other buildings.
In line with legal safety requirements, anyone performing any operation on a Stormshield Network Security range product must know and follow the safety indications below:
To the attention of maintenance teams:
WARNING
DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.
Only qualified personnel from an approved maintenance center can perform operations on this component.
If a hardware issue occurs on your firewall or if one of the accessories does not match its description, contact your certified partner.
Precautions for assembly in a cabinet
- Installation kit: use only the installation kit supplied with the product.
- Elevated Operating Ambient - If installed in a closed or multi-unit cabinet assembly, the operating ambient temperature of the cabinet environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
- Reduced Air Flow - Installation of the equipment in a cabinet should be such that the amount of air flow required for safe operation of the equipment is not compromised.
- Mechanical Loading - Mounting of the equipment in the cabinet should be such that a hazardous condition is not achieved due to uneven mechanical loading.
- Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
- Reliable Earthing - Reliable earthing of cabinet-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of terminal blocks)